Product Description
What the DS-K2M002X does
The DS-K2M002X is a Hikvision expansion module that adds control for two extra doors onto an existing Hikvision access control system. It talks back to the main controller over an RS-485 interface, which keeps data transmission stable across the network as a site grows.
Reader flexibility
Card readers connect via RS-485 (OSDP) or Wiegand. That dual-interface support means an installer can specify card readers, keypads or biometric readers to suit the project brief rather than being locked into one reader type — useful on jobs where the reader spec is set by the client, not the installer.
Panel installation
- DIN rail mounting, built for fitting inside a control cabinet or electrical panel
- LED indicators for power, communication, running and door status — handy during commissioning and later fault-finding
- Designed to sit as part of an integrated access control system rather than as a standalone unit
Power resilience
The module supports battery charging and discharging management, helping keep doors operational through short power interruptions where a backup battery is fitted.
Where it fits
This is the type of component specified when a single Hikvision controller needs to cover more doors than it natively supports — typical on multi-door commercial or industrial fit-outs such as offices, warehouses or retail units run from a shared control cabinet.
Specifications
- Linked Door Capacity
- 2 doors
- Linked Card Reader Capacity
- 4 RS-485 card readers (OSDP protocol) and 2 Wiegand card readers
- Battery
- Charge and discharge
- Power Supply
- 12 ± 15% VDC
- Max Power Consumption
- ≤ 50 W
- Operating Temperature
- -10 °C to 55 °C (14 °F to 131 ° F)
- Operating Humidity
- 0% to 90% (No condensing)
- Installation
- Installation with guide rail
- Configuration via Web Browser
- Support via access controller
- Multi-factor Authentication
- Support via access controller
- First Person In
- Support via access controller
- Multi-door Interlocking
- Support via access controller: supports 32 groups (32 doors each)
Technical Specifications
Frequently Asked Questions
How many doors does the DS-K2M002X add?
It extends a Hikvision access controller to manage two additional doors.
What reader interfaces does it support?
Card readers connect via RS-485 using the OSDP protocol or via Wiegand, so different reader types can be used on the same module.
How does it connect to the main controller?
It communicates with the main access controller through an RS-485 interface.
How is it mounted?
It uses standard DIN rail mounting, designed for installation inside a control cabinet or electrical panel.